苍山5.2级地震前临沂台深井地电异常
DOI:
作者:
作者单位:

作者简介:

通讯作者:

基金项目:


DEEP WELL GEOELECTRICITY ANOMALY IN LINYI STATION BEFORE THE CANGSHAN MS5.2 EARTHQUAKE
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    对苍山5.2级地震前距震中23km的临沂台深井地电观测资料进行了分析.结果表明,震前该台电阻率和自然电位出现了长达5年的与地震活动性异常同步的趋势异常.震前6个月电阻率出现下降异常.震前24天自然电位和电阻率同时急剧下降,震后又同时急剧回升.

    Abstract:

    Through analysis on deep-well geoelectricity data of Linyi station which is 23 km away from the epicentre of the Cangshan MS5.2 earthquake,it is shown that before the earthquake,the background tendency anomalies of the deep-well resistivity and natural geoelectric potential appeared synchronously with the seismicity anomaly for 5 years.The descending tendency anomaly of deep-well resistivity occurred six months before the earthquake.The natural geoelectric potential and resistivity reduced rapidly 24 days before the earthquake,and then rose again abruptly after the earthquake.

    参考文献
    相似文献
    引证文献
引用本文

孟庆武.苍山5.2级地震前临沂台深井地电异常[J].地震工程学报,1998,20(1):91-95. MENG Qingwu. DEEP WELL GEOELECTRICITY ANOMALY IN LINYI STATION BEFORE THE CANGSHAN MS5.2 EARTHQUAKE[J]. China Earthquake Engineering Journal,1998,20(1):91-95.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
历史
  • 收稿日期:1996-03-20
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2017-06-24